7 Best Practice Glass Plate Level Gauge Maintenance

  The glass plate level gauge instrument can be used for the medium level detection of various towers, tanks, spherical vessels and boilers. This series of liquid level gauge can achieve high sealing, anti-leakage and suitable for high temperature, high pressure, corrosion-resistant occasions. It makes up for the defects of poor clarity and easy rupture of the indication of the glass tube liquid level gauge, and there is no blind area in the whole process of measurement, the display is clear and the measurement range is large. 1. There should be no magnetic permeable materials around the glass plate level gauge body, disable iron wire to fix it, otherwise it will affect the normal operation of the level gauge; 2. If users use heat tracing piping by themselves, they must choose non-magnetic materials such as copper tubes. The heating temperature is determined according to the condition of the medium; 3. The glass plate level gauge must be installed vertically for easy maintenance ...

How to Install and Use Glass Plate Level Gauge

Image
  1. Open the package, check that the installation is correct, and the level gauge is intact. 2. If there are multiple valves from the equipment to the liquid level gauge, first open the valves other than the liquid level gauge's own or closest to the liquid level gauge. 3. Slowly open the upper needle valve until it is fully open. 4. Slowly open the lower liquid needle valve until it is fully open. 5. Perform the flushing operation of the liquid level gauge, and eliminate the possibility of blocking the impulse pipe during the flushing. Note: When opening the valve and flushing operation, the valve should be opened slowly to prevent blockage caused by the action of the leak-proof device of the level gauge. How does the  glass plate level gauge  purge the oil stain on the inner wall? During the start of construction, the inner wall of the glass plate level gauge was stained with oil, which caused difficulties in observing the liquid level. The way to remove oil pollution ...

What is the Production Method of Optical Glass?

Image
  As a   Fused Silica Glass Supplier , share it with you. Glass that can change the direction of light propagation and change the relative spectral distribution of ultraviolet, visible or infrared light. Optical glass in a narrow sense refers to colorless optical glass; optical glass in a broad sense also includes colored optical glass, laser glass, quartz optical glass, anti-radiation glass, ultraviolet and infrared optical glass, fiber optical glass, acousto-optic glass, magneto-optical glass, and photochromic glass. Optical glass can be used to manufacture lenses, prisms, mirrors and windows in optical instruments. Components made of optical glass are key elements in optical instruments. Optical Glass Blanks The raw materials for the production of optical glass are some oxides, hydroxides, nitrates and carbonates, and phosphates or fluorides are introduced according to the requirements of the formulation. In order to ensure the transparency of glass, the content of colored ...

The principle structure and characteristics of the magnetic flap level gauge

  The structure of the magnetic flap level gauge is composed of a float (main duct), a magnetic float, a magnetic flap (magnetic flap column), an indicator, a drain valve, and a connecting flange. The magnetic flap level gauge is easy to use and has the following outstanding features and advantages: 1. The float is used as the sensing element and the magnetic steel is used to drive the flip indicator, so no energy assistance is required; 2. Through technical measures such as high sealing and leakage prevention, the magnetic flap liquid level can work safely and reliably even in various harsh environments such as low temperature, high temperature, high pressure, and strong corrosion; 3. Because of the high compatibility of the magnetic flap level gauge, it has been widely used in industrial production. It is an ideal choice for tank, tank and other container level measurement. However, due to the complex working conditions on site, in actual measurement, different types of magnetic...

Introduction and installation precautions of magnetic flap level gauge

  The magnetic flap level gauge is a key instrument for liquid level meter detection. It is a two-color magnetic flip column with a magnetic float controller to identify the liquid level indicator. It can be used in all kinds of towers, tanks, tanks, and spheres. Detection of chemical substance level indicators of machinery and equipment such as containers and heat treatment furnaces. Therefore, grasping its basic principles according to this design concept is relatively popular: the magnetic flip-column liquid level transmitter uses top-mounted or side-mounted inlet valve tube when accurately measuring liquid. The main body of the magnetic turning column is refitted with the turning column liquid level indicator, the float level gauge and the liquid level transmitter. The magnetic control module is placed inside the pressure controller of the centrifugal water pump or connected to the pressure controller of the centrifugal water pump according to a small chain. When the pressure c...