How to Clean and Dry Quartz Glass Instruments?

Image
  As a   Fused Quartz Glass Supplier , share it with you. Quartz Glass After the instrument has been used for a period of time, it will appear to be dusty. The dust on the machine will cause a large error in the instrument, and it may also lead to a failure of the test. Therefore, the instrument must be clean and punctual in the process of use, so as to ensure the normal use of the instrument. Today, I will introduce us to the cleaning methods of quartz glass instruments and meters, and hope that these cleaning methods can help us. Quartz glass instrumentation Quartz glass instrumentation cleaning. Never use strong alkali to clean, because strong alkali will corrode the polished cuvette. It can only be soaked in lotion or 1% to 2% detergent, and then rinsed with tap water. At this time, use a small stick or cotton swab wrapped in silk cloth to rinse. The effect will be very good. Clean and clean the cuvette No water droplets hang on the inner and outer walls. The glass and pla...

How Many Coating Methods are Available on the Surface of Optical Glass?

Image
As a   Glass Lab Manufacturer , share with you. Coating is to coat a very thin transparent film on the surface to reduce light emission. There are many production methods for coated glass, mainly including vacuum magnetron sputtering method, vacuum evaporation method, chemical vapor deposition method and sol-gel method. Optical Glass Blanks 1. Magnetron sputtering coated glass can design and manufacture multi-layer complex film system by using magnetron sputtering technology, which can plate a variety of colors on the white glass substrate. The film has good corrosion resistance and wear resistance, which is suitable for production. And one of the more used products. 2. There is a certain gap between the variety and quality of vacuum evaporation coated glass and magnetron sputtering coated glass, which has been gradually replaced by vacuum sputtering. 3. The chemical vapor deposition method is to introduce reaction gas into the float glass production line to decompose on the hot gl...

Do you Know the Troubleshooting of Transparent Level Gauge?

Image
  As a   Level Gauge Glass Manufacturer , I would like to share with you. Routine inspection of level gauge and troubleshooting methods, suitable for magnetic flap level gauge, two-color quartz tube level gauge, glass tube level gauge, etc. 1. First check whether the power supply is connected correctly. If the connection method is found to be incorrect, modify it according to the operation manual. 2. Use a three-voltmeter to measure the voltage between +24V and O/P. The voltage should be between 13V and 36V. If the voltage is abnormal, check whether the circuit or related equipment is abnormal. 3. The second item should be confirmed to be normal, and then a milliamp meter should be connected to the 4~20MA circuit to check whether the current is normal. If the current value is abnormal, replace it with a new product or contact customer service personnel. Transparent Level Gauge 4. Use a voltmeter to check the voltage between IN and COM. Normally, it should be about 2.5V. If the...